Heat Pump Platform Symposium, Date: 2008/09/17 - 2008/09/17, Location: Sint-Katelijne-Waver, Belgium

Publication date: 2008-09-01

Proceedings of the Heat Pump Platform Symposium

Author:

Verhelst, Clara
De Ridder, F ; Helsen, Lieve

Keywords:

ground coupled heat pump system, borehole thermal energy storage modeling, system identification, optimal control, simulation of thermal systems

Abstract:

In this study we have explored to what extend the mean borefield and fluid outlet temperature of a borehole thermal energy storage system (BTESS) can be predicted with simple linear models. This is necessary to solve the optimal control problem for a BTESS by means of conventional optimization tools. The study shows that both fast transients (with a time-scale of one hour) and slow transients (with a time-scale of a year) can be predicted with a fifth order linear model resulting in an accuracy of ± 1°C if hourly measurements over the time span of half a year are available.