Download PDF

Physica Status Solidi A-Applications And Materials Science

Publication date: 2018-08-08
Volume: 215
Publisher: Wiley

Author:

van Grinsven, Bart
Eersels, Kasper ; Erkens-Hulshof, Sandra ; Dilien, Hanne ; Nurekeyeva, Kunya ; Cornelis, Peter ; Klein, Dionne ; Crijns, Francy ; Tuijthof, Gabrielle ; Wagner, Patrick ; Steen Redeker, Erik ; Cleij, Thomas J

Keywords:

Science & Technology, Technology, Physical Sciences, Materials Science, Multidisciplinary, Physics, Applied, Physics, Condensed Matter, Materials Science, Physics, bacterial culture, bacterial detection, heat-transfer methods, swab rinse kits, thermal interface resistance, HEAT-TRANSFER-METHOD, LABEL-FREE DETECTION, IMPRINTED POLYMERS, SYNTHETIC RECEPTORS, RECOGNITION, FILMS, 0204 Condensed Matter Physics, 0912 Materials Engineering, 1007 Nanotechnology, Applied Physics, 4016 Materials engineering, 4018 Nanotechnology, 5104 Condensed matter physics

Abstract:

© 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim Surface detection of bacteria has been proven difficult and time-consuming. Different recovery techniques yield varying numbers of bacteria. Subsequently, bacterial culturing, used for identification of these bacteria, will take several hours. In this article, the potential of a newly developed thermal biomimetic sensor for the detection of bacteria on surfaces is described. Previously this thermal biomimetic sensor has proven to be able to detect and quantify different bacteria in various liquid media such as buffer and spiked urine samples. In this article, laboratory surfaces are contaminated with increasing concentrations of Escherichia coli. Bacteria are recovered from the surfaces using commercially available swab rinse kits (SRK). A calibration curve is created by coating chips with surface-imprinted polymers (SIPs), serving as synthetic bacteria receptors, and exposing them to increasing concentrations of E. coli. Next, concentrations of E. coli in the SRK buffer are measured and quantified. The results show that it is possible to detect E. coli recovered from surfaces. Although quantification has been proven difficult as the dynamic range of the sensor is relatively narrow and the bacterial load obtained by using SRK is low, the sensor is able to give an indication about the concentration present on the surface. The results in this article illustrate that the thermal biomimetic sensor is a fast, low-cost, and label-free device useful in surface detection of E. coli, and seems a promising tool for future on-site bacterial detection.