Journal of the American Society of Echocardiography
Author:
Keywords:
Science & Technology, Life Sciences & Biomedicine, Cardiac & Cardiovascular Systems, Cardiovascular System & Cardiology, Particle imaging velocimetry, LV blood flow, LBBB, Apical rocking, Ventricular efficiency, CARDIAC RESYNCHRONIZATION THERAPY, OPTIMAL VORTEX FORMATION, CONTRAST ECHOCARDIOGRAPHY, QUANTITATIVE-ANALYSIS, INTEGRATIVE APPROACH, DIASTOLIC FUNCTION, ACTIVATION, SINUS, CARDIOMYOPATHY, DYSSYNCHRONY, Blood Flow Velocity, Bundle-Branch Block, Coronary Circulation, Echocardiography, Elasticity Imaging Techniques, Female, Heart Ventricles, Humans, Image Interpretation, Computer-Assisted, Male, Middle Aged, Reproducibility of Results, Sensitivity and Specificity, Ventricular Dysfunction, Left, 1102 Cardiorespiratory Medicine and Haematology, Cardiovascular System & Hematology, 3201 Cardiovascular medicine and haematology
Abstract:
Background: We aimed to assess the influence of left bundle branch block (LBBB)-like conduction abnormalities on left ventricular (LV) blood flow patterns and to characterize their potential impact on LV efficiency by measuring the changes in vortex formation and energy dissipation in the LV using echocardiographic Particle Image Velocimetry (Echo-PIV). Methods: We prospectively studied 36 subjects, including 20 pacemaker patients (PMP), 6 patients with LBBB and 10 healthy controls (NORM), all of whom had normal ejection fraction (EF>50%). In PMP, data were acquired, both in DDD and AAI mode. Standard grey scale, tissue Doppler myocardial imaging (DMI) and contrast enhanced Echo-PIV data were acquired and LV flow patterns were analyzed using dedicated software. Dyssynchrony was quantified by measuring apical transverse motion (ATM). Results: ATM was significantly higher in LBBB compared to NORM (4.9±1.9mm vs. 1.0±0.7mm, p<0.001). Quantitative measures of vortex energy dissipation (Relative Strength, Vortex Relative Strength and Vortex Pulsation Correlation) were significantly higher in LBBB (2.05±0.54, 0.53±0.13, 0.87±0.47) compared to NORM (1.48±0.28, 0.33±0.05, 0.24±0.51, all p<0.02). Vortex duration time in relation to the entire cardiac cycle was shorter in LBBB than in NORM (28% vs. 44%). All findings in LBBB and NORM were comparable to DDD and AAI. Conclusion: LV flow pattern analysis by Echo-PIV reveals that conduction delay by LBBB or due to pacemaker stimulation in the RV (DDD) disturbs the transfer of kinetic energy during the cardiac cycle and causes less efficient LV function. Our data contribute to a better understanding of hemodynamic consequences of conduction delays and may help optimizing therapeutic approaches.