Download PDF

Process Safety And Environmental Protection

Publication date: 2026-05-15
Volume: 212
ISSN: 0957-5820
Publisher: Elsevier

Author:

Vandevelde, Raf
Borremans, Siebe ; Vandenwayenberg, Cédric ; De Zutter, Hannes ; de Waal, Chantal ; Fastenaekels, Hans ; Vanierschot, Maarten ; Van Caneghem, Jo ; De Greef, Johan

Keywords:

HCl, Refuse-derived fuel (RDF), SO2, Thermal pilot reactor, Waste combustion, Waste-to-Energy, Science & Technology, Technology, Engineering, Environmental, Engineering, Chemical, Engineering, Waste-to-energy, MUNICIPAL SOLID-WASTE, TRACE-ELEMENTS, FULL-SCALE, GRATE, INCINERATION, RELEASE, WOOD, COCOMBUSTION, EMISSIONS, IGNITION, Strategic, Defence & Security Studies, 4004 Chemical engineering, 4011 Environmental engineering

Abstract:

An experimental study was carried out on packed-bed combustion of mixed dry wood chips (DWC) and refuse-derived fuel (RDF) in a thermal pilot reactor. Major combustion gases (O₂, CO, CO₂, H₂O), pollutants (HCl, SO₂, NOx), and temperature profiles were measured simultaneously over time and evaluated from an operation perspective. First, the fuel mix was varied under constant airflow. Stable combustion occurred at 80/20 and 60/40 DWC/RDF, with air-to-fuel ratios above six. Increasing RDF content raised CO and SO2 but lowered NOx and HCl. Next, airflow was varied from 5 to 20 m³ h⁻¹ at fixed initial fuel composition and amount. Optimal combustion occurred between 10 and 15 m³ h⁻¹ , reaching temperatures up to 1300 °C. Higher airflow reduced the maximum temperature to ∼1000 °C, decreased the ignition front speed by ∼50%, and did not (further) reduce the final ash amount, while promoting NOx and SO₂ formation and suppressing HCl release. These results are noteworthy, as time-resolved data from pilot packed-bed waste combustion combining temperature measurements with gas compounds, including particularly HCl and SO₂, are uncommon. They are also relevant for Waste-to-Energy operators, helping to mitigate boiler fouling and corrosion and to reduce consumptions of flue gas cleaning chemicals through optimized grate furnace operation.