Download PDF Download PDF

Experimental Physiology

Publication date: 2020-01-01
Volume: 105 Pages: 120 - 131
ISSN: 0958-0670
Publisher: Wiley

Author:

Cenni, Francesco
Bar-On, Lynn ; Monari, Davide ; Schless, Simon Henri ; Kalkman, Barbara ; Aertbeliën, Erwin ; Desloovere, Katleen ; Bruyninckx, Herman

Keywords:

Science & Technology, Life Sciences & Biomedicine, Physiology, medial gastrocnemius, tracking, ultrasound, validation, ACHILLES-TENDON, CEREBRAL-PALSY, AUTOMATIC TRACKING, CHILDREN, FASCICLE, IMAGES, LENGTH, WALKING, ADULTS, Achilles Tendon, Adult, Algorithms, Ankle, Cerebral Palsy, Child, Electronic Data Processing, Humans, Muscle, Skeletal, Rotation, Software, Ultrasonography, Walking, Young Adult, 0606 Physiology, 1106 Human Movement and Sports Sciences, 1116 Medical Physiology, 3109 Zoology, 3208 Medical physiology, 4207 Sports science and exercise

Abstract:

Clinically-relevant information can be extracted from ultrasound (US) images by tracking the displacement of the junction between muscle and tendon. This paper validated automatic methods for tracking the location of muscle-tendon junction (MTJ) between the medial gastrocnemius and the Achilles tendon during passive slow and fast stretches, and active ankle rotations while walking on a treadmill. First, a fully automatic algorithm based on an optical flow approach was applied on collected US images. Second, results of the fully automatic algorithm were evaluated and corrected using a quality measure that indicated which critical images need to be manually corrected. US images from 12 typically developed (TD) children, 12 children with spastic cerebral palsy (SCP) and 8 healthy adults were analysed. Fully and semi-automatic tracking were compared to manual tracking using root mean square errors (RMSE). For the fully automatic tracking, RMSE was less than 3.1 mm for the slow stretch and 5.2 mm for the fast stretch, being the worst case in SCP. The tracking results in the fast stretch condition were improved (especially in SCP) by using the semi-automatic approach, with an RMSE reduction of about 30%. During walking, the semi-automatic method also reduced errors, with a final RMSE of 3.6mm. In all cases, data processing was considerably shorter using the semi-automatic method (2 min) compared to manual tracking (20 min). A quick manual correction considerably improves tracking of the MTJ during gait and allows to achieve results suitable for further analyses. The proposed algorithm is freely available.