Download PDF

Outdoor thermal and electrical characterisation of photovoltaic modules and systems

Publication date: 2016-02-16

Author:

Herteleer, Bert
Cappelle, Jan ; Catthoor, Francky ; Driesen, Johan

Keywords:

photovoltaic module and system analysis, normalised efficiency, performance ratio, temperature correction

Abstract:

Current and future investors in photovoltaic systems are interested in how well the system performs, and how predictable this is over the expected lifetime. To do so, models have been developed and measurements of photovoltaic systems have been done. This dissertation presents the outdoor measurement set-up that has been developed for thermal and electrical characterisation of photovoltaic modules and systems, aimed at measuring transient effects and changes. The main design decisions and implementations are discussed, including the ability to measure in-situ current-voltage (I-V) curves of photovoltaic modules connected to inverters and DC-DC converters, in an automated manner, without the need for physical removal from the array. The main factors that influence photovoltaic system performance, such as irradiance, ambient temperature, wind speed and direction and module temperatures are measured and logged per second. Together with the power and energy yield measurement of a large number of photovoltaic modules and inverters at a similar rate, high resolution data is obtained on the performance of these modules and inverters. The DC values of the modules and inverters are obtained by custom-built, low-cost, galvanically isolated signal conditioning boards. For temperature measurements, methods are adapted or introduced for steady state and transient conditions. Methods to verify, and where necessary, correct measurements are shown, which result in lowered measurement uncertainties. The intra-module and inter-module temperature behaviour of the studied modules is discussed, with results showing a dependence on the irradiance conditions, as well as the wind speed and direction. The framework of the projected wind vector is introduced and applied to the thermal analysis of the modules studied. The electrical performance of the photovoltaic modules and systems is discussed in detail, with the introduction of a variety of tools and methods. Chief among these is the normalised efficiency ηN, which is the power equivalent of the industry-standard energy production evaluation metric, the Performance Ratio (PR). The normalised efficiency ηN can be used for system inter-comparisons, real-time monitoring, anomaly detection (such as shading), and to obtain the system temperature coefficient of power γsyst. The principle of temperature correction on power and energy values using measured temperatures is introduced, which is a powerful method which allows systems to be analysed, as if they had performed at the reference temperature. As a result, influencing factors which may be masked by the temperature can come to the fore - for example, the temperature-corrected Performance Ratio (PR*) shows a much more stable response in time than the regular PR, whereby performance effects can be largely decoupled from temperature variations over the period studied. A new method is introduced to obtain the coefficients for the power rating model for crystalline silicon modules from Huld et al, which allows the normalised efficiency ηN and normalised power PN to more easily be modelled. The approach is expanded in application from modules to systems. The method of this dissertation is shown to be easier to implement, with less stringent measurement requirements, e.g. no need for I-V curve measurement data. The number of model coefficients that must be determined is also lowered from six to three, with no negative impact on the model results - in fact, the modified model generally outperforms the original model of Huld et al. The results of this work give better system-specific results as seen in the validation testing, from the normalised efficiency to power, energy and Performance Ratio. With the validated approach, the energetic impact of partial shading is quantified for the modules and systems studied.