Title: Radiological Protection in Cone Beam Computed Tomography (CBCT). ICRP Publication 129
Authors: Rehani, M M ×
Gupta, R
Bartling, S
Sharp, G C
Pauwels, Ruben
Berris, T
Boone, J M #
Issue Date: Jul-2015
Publisher: Pergamon Press
Series Title: Annals of the ICRP vol:44 issue:1 pages:9-127
Article number: 10.1177/0146645315575485
Abstract: The objective of this publication is to provide guidance on radiological protection in the new technology of cone beam computed tomography (CBCT). Publications 87 and 102 dealt with patient dose management in computed tomography (CT) and multi-detector CT. The new applications of CBCT and the associated radiological protection issues are substantially different from those of conventional CT. The perception that CBCT involves lower doses was only true in initial applications. CBCT is now used widely by specialists who have little or no training in radiological protection. This publication provides recommendations on radiation dose management directed at different stakeholders, and covers principles of radiological protection, training, and quality assurance aspects. Advice on appropriate use of CBCT needs to be made widely available. Advice on optimisation of protection when using CBCT equipment needs to be strengthened, particularly with respect to the use of newer features of the equipment. Manufacturers should standardise radiation dose displays on CBCT equipment to assist users in optimisation of protection and comparisons of performance. Additional challenges to radiological protection are introduced when CBCT-capable equipment is used for both fluoroscopy and tomography during the same procedure. Standardised methods need to be established for tracking and reporting of patient radiation doses from these procedures. The recommendations provided in this publication may evolve in the future as CBCT equipment and applications evolve. As with previous ICRP publications, the Commission hopes that imaging professionals, medical physicists, and manufacturers will use the guidelines and recommendations provided in this publication for implementation of the Commission's principle of optimisation of protection of patients and medical workers, with the objective of keeping exposures as low as reasonably achievable, taking into account economic and societal factors, and consistent with achieving the necessary medical outcomes.
ISSN: 0146-6453
Publication status: published
KU Leuven publication type: IT
Appears in Collections:Oral and Maxillo-facial Surgery - Imaging & Pathology (OMFS-IMPATH)
× corresponding author
# (joint) last author

Files in This Item:
File Description Status SizeFormat
ICRP_129.pdf Published 1047KbAdobe PDFView/Open Request a copy

These files are only available to some KU Leuven Association staff members


All items in Lirias are protected by copyright, with all rights reserved.