Multisensory Research
Author:
Keywords:
Science & Technology, Social Sciences, Life Sciences & Biomedicine, Biophysics, Psychology, Psychology, Experimental, Reproducibility of results, proprioception, muscle spindle, postural balance, vibration, magnetic resonance imaging, LOW-BACK-PAIN, POSITION SENSE, POSTURAL SWAY, BALANCE, YOUNG, MOTOR, CORTEX, INSTABILITY, PARKINSONS, MOVEMENT, Female, Humans, Magnetic Resonance Imaging, Male, Muscle, Skeletal, Postural Balance, Proprioception, Reproducibility of Results, Vibration, Young Adult, 1109 Neurosciences, 1701 Psychology, 1702 Cognitive Sciences, 3209 Neurosciences, 5202 Biological psychology, 5204 Cognitive and computational psychology
Abstract:
Background and aims: Optimal postural control requires the brain to process proprioceptive signals. To study this central processing, functional magnetic resonance imaging (fMRI) combined with local muscle vibration, a strong stimulus for muscle spindles, is of great value. Due to the high-strength magnetic field of fMRI, the use of electromotor driven muscle vibrators is problematic in this environment. Pneumatic muscle vibrators provide a fMRI-compatible alternative. However, their ability to produce reliable and valid proprioceptive stimuli has not been investigated yet. This study aimed to determine test-retest reliability and concurrent validity of the postural response of pneumatic vibration on ankle and back muscles. Methods: Mean center of pressure (CoP) displacement in response to respectively ankle and back muscle vibration (45-60 Hz, 0.5 mm, 15 sec) during standing on stable and unstable support surface were determined in ten healthy subjects (aged 23±3 years). This test procedure was performed first with electromagnetic vibrators, and was repeated after a 5 minute break with MRI-compatible, custom-made pneumatic vibrators. The entire test was repeated within one week. Intraclass correlation coefficients (ICC) were calculated to determine (1) intraday and interday reliability for CoP displacement during both electromagnetic vibration and pneumatic vibration, and (2) concurrent validity of CoP displacement during pneumatic compared to electromagnetic vibration. The classification of Fleiss was used to interpret the ICC findings: ICC< 0.40 represents poor reliability, ICC 0.40-0.75 fair to good reliability and ICC> 0.75 excellent reliability. Results: Intraday and interday ICC values for CoP displacement in response to ankle muscle and back muscle vibration during stable and unstable standing ranged from 0.64-0.94 for electromagnetic vibration and from 0.64-0.90 for pneumatic vibration, respectively. Concurrent validity ICC values for CoP displacement during ankle muscle vibration ranged from 0.67-0.95 during stable standing and from 0.69-0.87 during unstable standing. For back muscle vibration, concurrent validity ICC values ranged from 0.63-0.65 during stable standing, whilst the ICC values during unstable standing were not statistically significant (p> 0.034). Discussion: Test-retest reliability for CoP displacement during pneumatic vibration was good to excellent and resembled the test-retest reliability of CoP displacement during electromagnetic vibration. The concurrent validity of pneumatic compared to electromagnetic vibration was good to excellent on ankle muscles in stable and unstable standing, and on back muscles in stable standing. This study shows that the custom-made, MRI-compatible pneumatic vibrator is able to stimulate muscle spindles during postural control reliably and validly. Consequently, this device can be used to study the central processing of proprioceptive signals in an fMRI environment.