ITEM METADATA RECORD
Title: Small-diameter titanium Grade IV and titanium-zirconium implants in edentulous mandibles: three-year results from a double-blind, randomized controlled trial
Authors: Quirynen, Marc ×
Al-Nawas, Bilal
Meijer, Henny J A
Razavi, Amir
Reichert, Torsten E
Schimmel, Martin
Storelli, Stefano
Romeo, Eugenio
the Roxolid Study Group #
Issue Date: Jul-2015
Publisher: Munksgaard
Series Title: Clinical Oral Implants Research vol:26 issue:7 pages:831-840
Article number: 10.1111/clr.12367
Abstract: The aim of this study was to compare crestal bone-level changes, soft tissue parameters and implant success and survival between small-diameter implants made of titanium/zirconium (TiZr) alloy or of Grade IV titanium (Ti) in edentulous mandibles restored with removable overdentures.
URI: 
ISSN: 0905-7161
Publication status: published
KU Leuven publication type: IT
Appears in Collections:Periodontology
× corresponding author
# (joint) last author

Files in This Item:
File Description Status SizeFormat
Quirynen,Al-Nawas 2015.docxpreprint Published 38KbUnknownView/Open

 


All items in Lirias are protected by copyright, with all rights reserved.