Download PDF (external access)

Innovative Food Science & Emerging Technologies

Publication date: 2011-01-01
Volume: 12 Pages: 531 - 541
Publisher: Elsevier Science

Author:

Gayán, Elisa
Monfort, S ; Alvarez, I ; Condon, S

Keywords:

UV light, Pasteurization, E. coli, Food Science, 03 Chemical Sciences, 06 Biological Sciences, 09 Engineering

Abstract:

The influence of treatment parameters (dose and temperature), treatment medium characteristics (absorption coefficient, pH and water activity) and microbiological factors (strain, growth phase and UV damage and repair capacity) on Escherichia coli UV-C resistance has been investigated. UV-C doses to inactivate at 25 °C 99.99% of the initial population (4D) of five strains of E. coli in McIlvaine buffer of pH 7.0 with tartrazine added (absorption coefficient of 10.77 cm -1) were 16.60, 14.36, 14.36, 13.22, 11.18 J/mL for strains E. coli STCC 4201, STCC 471, STCC 27325, O157:H7 and ATCC 25922, respectively. The entrance in the stationary growth phase increased the 4D value of the most resistant strain, E. coli STCC 4201, from 13.09 to 17.23 J/mL. Survivors to UV treatments showed neither oxidative damages nor injuries in cell envelopes. On the contrary, the photoreactivation by the incubation of plates for 60 min below visible light (11.15 klx) increased the dose to 18.97 J/mL. The pH and the water activity of the treatment medium did not affect the UV tolerance of E. coli STCC 4201, but the lethal effect of the treatments decreased exponentially (Log 10 4D = - 0.0628α + 0.624) by increasing the absorption coefficient (α). A treatment of 16.94 J/mL reached 6.35, 4.35, 2.64, 1.93, 1.63, 1.20, 1.02 and 0.74 Log 10 cycles of inactivation with absorption coefficients of 8.56, 10.77, 12.88, 14.80, 17.12, 18.51, 20.81 and 22.28 cm -1. The temperature barely changed the UV resistance up to 50.0 °C. Above this threshold, inactivation rates due to the combined process synergistically increased with the temperature. The magnitude of the synergism decreased over 57.5 °C. An UV treatment of 16.94 J/mL in media with an absorption coefficient of 22.28 cm -1 reached 1.23, 1.64, 2.36, 4.01 and 6.22 Log 10 cycles of inactivation of E. coli STCC 4201 at 50.0, 52.5, 55.5, 57.5 and 60.0 °C, respectively. Industrial relevance: Results obtained in this investigation show that UV light applied at mild temperatures (57.5 to 60 °C) could be an alternative to heat treatments for 5-Log 10 reductions of E. coli in liquid foods. Since microbial resistance to UV-C light did not depend on the pH and water activity (a w) of the treatment media, eventual advantages of UV light for pasteurization purposes will be higher in low a w foods. E. coli STCC 4201 could be considered as a target when UV light processing of foods. © 2011 Elsevier Ltd. All rights reserved.