ITEM METADATA RECORD
Title: Kinematics of the three components of a total ankle replacement: in vivo fluoroscopic analysis
Authors: Cenni, Francesco ×
Leardini, Alberto
Belvedere, Claudio
Bugane', Francesca
Cremonini, Karin
Miscione, Maria Teresa
Giannini, Sandro #
Issue Date: Apr-2012
Publisher: Williams & Wilkins
Series Title: Foot & Ankle International vol:33 issue:4 pages:290-300
Abstract: BACKGROUND:
Careful kinematic analysis of ankle joints with newly developed prostheses should be carried out to assess the actual performance in vivo. This study analyzed the pattern of motion of the three components of a ligament-compatible ankle replacement, developed to replicate normal joint kinematics.
MATERIALS AND METHODS:
Twelve patients treated with this design were analyzed at 6, 12, and 24 months followup. A series of images were acquired by videofluoroscopy at extremes of the range of motion, and during flexion/extension against gravity and stair-climbing/descending. Three-dimensional positions and orientations of the tibial and talar metal components and of the polyethylene mobile-bearing were obtained from the images by a standard shape-matching procedure. Motion between the three components was calculated and descriptively analyzed.
RESULTS:
Large tibiotalar joint mobility of the replaced ankle was observed in all three anatomical planes, particularly in the sagittal. In flexion/extension against gravity, the mean range of flexion was 17.6, 17.7, and 16.2 degrees, respectively, over the three followups. The inclination angle of the mean axis of joint rotation was 3.7 degrees down and lateral in the frontal plane and 4.7 degrees posterior and lateral in the transverse plane, similar to those in the normal ankle. The corresponding antero-posterior translation of the meniscal-bearing with respect to the tibia was 3.3, 3.3, and 3.2 mm, with statistically significant correlation with joint flexion.
CONCLUSION:
Physiological motion can be achieved in ligament-compatible ankle joint replacements. The considerable antero-posterior bearing-to-tibial motion and its coupling with flexion support the main original claims of this design.
ISSN: 1071-1007
Publication status: published
KU Leuven publication type: IT
Appears in Collections:Non-KU Leuven Association publications
× corresponding author
# (joint) last author

Files in This Item:

There are no files associated with this item.

Request a copy

 




All items in Lirias are protected by copyright, with all rights reserved.

© Web of science