Abstract: Reliable post-implant evaluation of prostate seed implants requires optimal seed identification and accurate delineation of anatomical structures. In this study the GEC-ESTRO groups BRAPHYQS and PROBATE investigated the interobserver variability in post-implant prostate contouring, seed reconstruction and image fusion and its impact on the dose-volume parameters.