Title: Evaluation of Three MRI-Based Anatomical Priors for Quantitative PET Brain Imaging
Authors: Vunckx, Kathleen ×
Atre, Ameya
Baete, Kristof
Reilhac, Anthonin
Deroose, Christophe
Van Laere, Koen
Nuyts, Johan #
Issue Date: Mar-2012
Publisher: Institute of Electrical and Electronics Engineers
Series Title: IEEE Transactions on Medical Imaging vol:31 issue:3 pages:599-612
Abstract: In emission tomography, image reconstruction and therefore also tracer development and diagnosis may benefit from the use of anatomical side information obtained with other imaging modalities in the same subject, as it helps to correct for the partial volume effect. One way to implement this, is to use the anatomical image for defining the a-priori distribution in a maximum-a-posteriori (MAP) reconstruction algorithm. In this contribution, we use the PET-SORTEO Monte Carlo simulator to evaluate the quantitative accuracy reached by three different anatomical priors when reconstructing positron emission tomography (PET) brain images, using volumetric magnetic resonance imaging (MRI) to provide the anatomical information. The priors are: 1) a prior especially developed for FDG PET brain imaging, which relies on a segmentation of the MR-image [1]; 2) the joint entropy-prior [2]; 3) a prior that encourages smoothness within a position dependent neighborhood, computed from the MR-image. The latter prior was recently proposed by our group in [3], and was based on the prior presented by Bowsher et al. [4]. The two latter priors do not rely on an explicit segmentation, which makes them more generally applicable than a segmentation-based prior. All three priors produced a compromise between noise and bias that was clearly better than that obtained with post-smoothed maximum likelihood expectation maximization (MLEM) or MAP with a relative difference prior. The performance of the joint entropy prior was slightly worse than that of the other two priors. The performance of the segmentation-based prior is quite sensitive to the accuracy of the segmentation. In contrast to the joint entropy-prior, the Bowsher-prior is easily tuned and does not suffer from convergence problems.
ISSN: 0278-0062
Publication status: published
KU Leuven publication type: IT
Appears in Collections:Nuclear Medicine & Molecular Imaging
× corresponding author
# (joint) last author

Files in This Item:

There are no files associated with this item.

Request a copy


All items in Lirias are protected by copyright, with all rights reserved.

© Web of science