Title: Implant stability is affected by local bone microstructural quality
Authors: Wirth, Andreas J ×
Goldhahn, Joerg
Flaig, Cyril
Arbenz, Peter
Mueller, Ralph
van Lenthe, Harry #
Issue Date: Sep-2011
Publisher: Pergamon Press
Series Title: Bone vol:49 issue:3 pages:473-478
Abstract: It is known that low bone quality, caused for instance by osteoporosis, not only increases the risk of fractures, but also decreases the performance of fracture implants; yet the specific mechanisms behind this phenomenon are still largely unknown. We hypothesized that especially pen-implant bone microstructure affects implant stability in trabecular bone, to a greater degree than more distant bone. To test this hypothesis we performed a computational study on implant stability in trabecular bone. Twelve humeral heads were measured using micro-computed tomography. Screws were inserted digitally into these heads at 25 positions. In addition, at each screw location, a virtual biopsy was taken. Bone structural quality was quantified by morphometric parameters. The stiffness of the 300 screw-bone constructs was quantified as a measure of implant stability. Global bone density correlated moderately with screw-bone stiffness (r(2)=0.52), whereas local bone density was a very good predictor (r(2)=0.91). The best correlation with screw-bone stiffness was found for local bone apparent Young's modulus (r(2)=0.97), revealing that not only bone mass but also its arrangement in the trabecular microarchitecture are important for implant stability. In conclusion, we confirmed our hypothesis that implant stability is affected by the microstructural bone quality of the trabecular bone in the direct vicinity of the implant. Local bone density was the best single morphometric predictor of implant stability. The best predictability was provided by the mechanical competence of the pen-implant bone. A clinical implication of this work is that apparently good bone stock, such as assessed by DXA, does not guarantee good local bone quality, and hence does not guarantee good implant stability. New tools that could quantify the structural or mechanical quality of the pen-implant bone may help improve the surgical intervention in reaching better clinical outcomes for screw fixation. (C) 2011 Elsevier Inc: All rights reserved.
URI: 
ISSN: 8756-3282
Publication status: published
KU Leuven publication type: IT
Appears in Collections:Biomechanics Section
× corresponding author
# (joint) last author

Files in This Item:

There are no files associated with this item.

Request a copy

 




All items in Lirias are protected by copyright, with all rights reserved.

© Web of science