Title: Comparison of averaging procedures for SAR distributions at 900 and 1800 MHz
Authors: Stevens, Nobby ×
Martens, Luc #
Issue Date: Nov-2000
Publisher: Professional Technical Group on Microwave Theory and Techniques, Institute of Electrical and Electronics Engineers
Series Title: IEEE Transactions on Microwave Theory and Techniques vol:48 issue:11 pages:2180-2184
Abstract: In this paper, we study the effect of the position of the averaging volume on the averaged specific-absorption-rate values at the typical European cellular telephone frequencies around 900 and 1800 MHz. The Council of the European Union recommends a 10-g contiguous volume, as the averaging volume. A simple cubic tissue ran be used provided that the calculated dosimetric quantities have conservative values relative to the exposure guidelines of the Council of the European Union. Large differences can occur depending on the averaging procedure. The situation is definitely most critical at 1800 MHz.