Title: The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery
Authors: Wyffels, P A H ×
Sergeant, Paul
Wouters, P F #
Issue Date: Jul-2010
Publisher: Published for the Association of Anaesthetists of Great Britain and Ireland by Academic Press (and Grune & Stratton)
Series Title: Anaesthesia vol:65 issue:7 pages:704-9
Abstract: SUMMARY: We investigated the ability of pulse pressure variation and stroke volume variation to predict fluid responsiveness during mechanical ventilation in patients undergoing open chest surgery by comparing their respective correlations with cardiac output changes induced by leg elevation. Serial leg elevation manoeuvres were performed before and after sternotomy in 15 patients scheduled for elective off-pump coronary bypass surgery. Under closed chest conditions, both pulse pressure variation and stroke volume variation correlated well with the induced cardiac output changes (r = 0.856, p = 0.002 and r = 0.897, p = 0.0012, respectively). These correlations were lost for both parameters following sternotomy. Our data show that pulse pressure variation and stroke volume variation are valid predictors of fluid responsiveness under closed chest conditions but that this property no longer holds when the chest is open.
URI: 
ISSN: 0003-2409
Publication status: published
KU Leuven publication type: IT
Appears in Collections:Clinical Cardiac Surgery
× corresponding author
# (joint) last author

Files in This Item:

There are no files associated with this item.

Request a copy

 




All items in Lirias are protected by copyright, with all rights reserved.