Title: Accuracy of seed reconstruction in prostate postplanning studied with a CT- and MRI-compatible phantom
Authors: De Brabandere, Marisol ×
Kirisits, Christian
Peeters, Ronald
Haustermans, Karin
Van den Heuvel, Frank #
Issue Date: May-2006
Publisher: Elsevier Science Publishers
Series Title: Radiotherapy and Oncology vol:79 issue:2 pages:190-7
Abstract: BACKGROUND AND PURPOSE: Postimplant dosimetry of prostate seed implants is usually performed by seed localisation on transversal CT or MR images. In order to obtain reliable dosimetric evaluation data, it is important that seeds are reconstructed accurately. Currently, there is no comparative data available on seed localisation accuracy of CT-and MRI-based reconstructions, mainly due to the lack of a suitable QA tool. In this study, we developed a CT-and MRI compatible prostate phantom to investigate the intrinsic accuracy of seed detection for both imaging modalities. PATIENTS AND METHODS: A 60 seed geometry was created according to a clinically meaningful plan, including rotated and shifted seeds. After implantation of the seeds in the phantom, CT and MRI scans with 3, 4 and 5mm slice thickness were performed. The seed locations were reconstructed in the treatment planning system and compared with the known reference positions. RESULTS: Due to the comparable density and relaxation times of the phantom material to prostate tissue, the seeds are visualised similarly as on real patient images. The observed mean reconstruction uncertainties were in general smaller for CT (0.9+/-0.6, 0.9+/-0.6, 2.1+/-0.8 mm on 3, 4 and 5mm scans, respectively), than for MRI (Philips 1.5 T: 2.1+/-1.4, 1.6+/-1.2, 1.9+/-0.9 mm on 3, 4 and 5 mm scans, respectively, and Siemens 1.5 T: 2.3+/-0.8, 2.0+/-1.6, 1.6+/-0.8 mm on 3, 4 and 5mm scans, respectively). CONCLUSIONS: For our clinical sequences of both CT and MRI, the mean deviation of the reconstructed seed positions were all within acceptable limits for clinical use (<2.3 mm). The phantom was found to be a suitable quality assurance tool to assess the reliability and accuracy of the seed reconstruction procedure. Moreover, as the phantom material has the same imaging characteristics as real prostate tissue, it is a useful device to define proper MRI sequences.
ISSN: 0167-8140
Publication status: published
KU Leuven publication type: IT
Appears in Collections:Laboratory of Experimental Radiotherapy
× corresponding author
# (joint) last author

Files in This Item:

There are no files associated with this item.

Request a copy


All items in Lirias are protected by copyright, with all rights reserved.

© Web of science