Title: The shape of the aortic outflow velocity profile revisited: is there a relation between its asymmetry and ventricular function in coronary artery disease?
Authors: Cikes, Maja ×
Kalinic, Hrvoje
Baltabaeva, Aigul
Loncaric, Sven
Parsai, Chirine
Milicic, Davor
Cikes, Ivo
Sutherland, George
Bijnens, Bart #
Issue Date: Oct-2009
Publisher: W.B. Saunders Co.
Series Title: European Journal of Echocardiography vol:10 issue:7 pages:847-857
Abstract: AIMS: Myocardium contracts in the beginning of ejection causing outflow acceleration, resulting in asymmetric outflow velocity profiles peaking around one-third of ejection and declining when force development declines. This article aimed to demonstrate that decreased contractility in coronary artery disease (CAD) changes outflow timing and profile symmetry. METHODS AND RESULTS: Seventy-nine patients undergoing routine full dose dobutamine stress-echo (DSE) were divided into two groups based on resting wall motion and DSE response: DSE negative (DSE(neg)) (35 of 79 patients) and positive (DSE(pos)) (44 of 79 patients) which were compared with 32 healthy volunteers. Aortic CW-Doppler traces at rest were analysed semi-automatically; time-to-peak (T(mod)), ejection-time (ET(mod)), rise-time (t(rise)), and fall-time (t(fall)) were quantified. Asymmetry (asymm) was calculated as the normalized difference of left and right half of the spectrum. Normal curves were triangular, early-peaking, whereas patients showed more rounded shapes and later peaks. T(rise) was longest in DSE(pos). T(fall) was shortest in DSE(pos), followed by controls and DSE(neg). Asymm was lowest in DSE(pos), followed by controls and DSE(neg). Abnormally symmetric profiles (asymm <0.25) were found in none of the controls, 2.9% DSE(neg), and 27.3% DSE(pos). A good correlation was found between assym and ejection fraction (EF) and T(mod)/ET(mod) and EF. Notably, an LV dynamic gradient was induced in 71.4% DSE(neg) and in 18.2% DSE(pos), associated with LV hypertrophy and supernormal (very asymmetric) traces. CONCLUSION: Decreased myocardial function results in a more symmetrical outflow, while very asymmetrical traces suggest increased contractility, potentially inducing intra-cavity gradients during DSE. Therefore, including outflow symmetry as a clinical measurement provides additional information on patients with CAD.
ISSN: 1525-2167
Publication status: published
KU Leuven publication type: IT
Appears in Collections:Cardiovascular Imaging and Dynamics
× corresponding author
# (joint) last author

Files in This Item:

There are no files associated with this item.

Request a copy


All items in Lirias are protected by copyright, with all rights reserved.

© Web of science