ITEM METADATA RECORD
Title: Accurate measurement of the steady-state swelling behavior of SU-8 negative photo resist
Authors: Wouters, Kristof
Puers, Robert #
Issue Date: 6-Sep-2009
Publisher: ELSEVIER
Host Document: proceedings Eurosensor 2009 pages:60-63
Conference: Eurosensors09 edition:13 location:Lausanne, Switzerland date:September 6 - 9, 2009
Abstract: The swelling behaviour of SU-8 2000 series is investigated. This is done using on-wafer micro machined stress indicator structures. The indicator structures convert the stress in the material to a measurable displacement. When SU-8 is submersed into a solvent, the polymer matrix of the SU-8 can absorb some of the solvent molecules. As a result, the SU-8 can expand and the built in tensile stress is partially relieved. The swelling can thus be measured directly and independently of lithography parameters. For this study, the indicator structures are immersed in Propyle Glycol Methyl Ether Acetate (PGMEA), isopropyl alcohol (IPA) and water.
Publication status: published
KU Leuven publication type: IC
Appears in Collections:ESAT - MICAS, Microelectronics and Sensors
# (joint) last author

Files in This Item:
File Description Status SizeFormat
8304.pdfMain article Published 237KbAdobe PDFView/Open

 


All items in Lirias are protected by copyright, with all rights reserved.

© Web of science