ITEM METADATA RECORD
Title: Effect of nodule characteristics on variability of semiautomated volume measurements in pulmonary nodules detected in a lung cancer screening program
Authors: Wang, Ying ×
van Klaveren, Rob J
van der Zaag-Loonen, Hester J
de Bock, Geertruida H
Gietema, Hester A
Xu, Dong Ming
Leusveld, Anne L M
de Koning, Harry J
Scholten, Ernst T
Verschakelen, Johny
Prokop, Mathias
Oudkerk, Matthijs #
Issue Date: Aug-2008
Publisher: Radiological Society of North America
Series Title: Radiology vol:248 issue:2 pages:625-31
Abstract: PURPOSE: To retrospectively assess volume measurement variability in solid pulmonary nodules (volume, 15-500 mm(3)) detected at lung cancer screening and to quantify the independent effects of nodule morphology, size, and location. MATERIALS AND METHODS: This retrospective study was a substudy of the screening program that was approved by the Dutch Ministry of Health, and all participants provided written informed consent. Two independent readers used semiautomated software to measure the volume of pulmonary nodules detected in 6774 participants aged 50-75 years (5917 men). Nodules were classified according to their location (purely intraparenchymal, pleural based, juxtavascular, or fissure attached), morphology (smooth, polylobulated, spiculated, or irregular), and size (<or=50 mm(3) or >50 mm(3)). The level of agreement was expressed by using the absolute values of the relative volume differences (RVDs). Multivariate logistic regression analysis was performed, and odds ratios (ORs) were computed to quantify the independent effects of morphology, location, and size on RVD categories. RESULTS: Altogether, 4225 nodules in 2239 participants were included. Complete agreement in volume was obtained for 3646 (86%) of the nodules. Disagreement was small (absolute value of RVD < 5%) for 173 (4%) nodules, moderate (absolute value of RVD >or= 5% but < 15%) for 232 (6%), and large (absolute value of RVD >or= 15%) for 174 (4%). Multivariate analysis showed that the ORs of volume disagreement were 15.7, 3.1, and 1.9 for irregular, spiculated, and polylobulated nodules, respectively; 3.5, 2.6, and 2.1 for juxtavascular, pleural-based, and fissure-attached nodules, respectively; and 1.3 for large nodules compared with smooth, purely intraparenchymal, and small reference nodules. CONCLUSION: Nodule morphology, location, and size influence volume measurement variability, particularly for juxtavascular and irregular nodules.
URI: 
ISSN: 0033-8419
Publication status: published
KU Leuven publication type: IT
Appears in Collections:Radiology
× corresponding author
# (joint) last author

Files in This Item:

There are no files associated with this item.

Request a copy

 




All items in Lirias are protected by copyright, with all rights reserved.

© Web of science