Title: An aged rat model of partial androgen deficiency: prevention of both loss of bone and lean body mass by low-dose androgen replacement
Authors: Vanderschueren, Dirk ×
Vandenput, Liesbeth
Boonen, Steven
Van Herck, Erik
Swinnen, Johan
Bouillon, Roger #
Issue Date: May-2000
Series Title: Endocrinology vol:141 issue:5 pages:1642-7
Abstract: The aim of this study was to evaluate the effects of different doses of androgen replacement, both on body composition and bone, in an aged male orchidectomized rat model. Testosterone was administered by 0.5, 1, and 2.5-cm sc SILASTIC implants (release of, respectively, 11.5, 23, and 55 microg/day) to aged (12 months old, +/- 550 g) male orchidectomized Wistar rats during a 15-week experimental period. T 0.5 only partially prevented decrease of ventral prostate and seminal vesicle weight, compared with an intact group that received an empty implant (Intact). The 1-cm implant (T 1) completely prevented decrease of both seminal vesicles and ventral prostate weight. The 2.5-cm implant (T 2.5) was clearly supraphysiological, as demonstrated by significant hypertrophy of both androgen-sensitive organs. Serum testosterone was lower in T 0.5 and T 1 (0.38 +/- 0.06 ng/ml and 0.92 +/- 0.06 ng/ml, respectively) and higher in T 2.5 (2.4 +/- 0.28. ng/ml), compared with both Intact (1.6 +/- 0.23 ng/ml) and the baseline group(1.6 +/- 0.11 ng/ml). As expected, orchidectomized rats that received an empty SILASTIC implant had significantly lower bone mineral content (-7.9%), apparent density (-5.7%), and lean body mass (-10.8%), as measured by dual-energy x-ray absorptiometry, without significant changes in body weight and fat mass, compared with Intact. Also, cancellous (-50.3%) and cortical (-1.8%) volumetric density, as measured by peripheral quantitative computed tomography, were decreased in the tibia. Bone turnover, as measured by serum osteocalcin and urinary deoxypyridinoline excretion, was increased in orchidectomized rats that received an empty SILASTIC implant. T 0.5 prevented all changes, not only in bone mineral content, density, and turnover but also in lean body mass. Moreover, there were no significant differences, for all these parameters, between the different doses of testosterone replacement. In conclusion, low-dose androgen replacement does not lead to lower bone mineral density, higher bone turnover, and lower lean body mass in aged male rats, whereas complete androgen deficiency does. Therefore, the threshold concentration of testosterone necessary for prevention of both bone and lean body mass loss in aged male rats is clearly lower than for prostate and seminal vesicles.
ISSN: 0013-7227
Publication status: published
KU Leuven publication type: IT
Appears in Collections:Clinical and Experimental Endocrinology
Gerontology and Geriatrics
Laboratory of Lipid Metabolism and Cancer (+)
× corresponding author
# (joint) last author

Files in This Item:

There are no files associated with this item.

Request a copy


All items in Lirias are protected by copyright, with all rights reserved.

© Web of science