Title: The use of microfocus computerized tomography as a new technique for characterizing bone tissue around oral implants
Authors: Van Oosterwyck, Hans ×
Duyck, Joke
Vander Sloten, Jos
Van der Perre, Georges
Jansen, J.
Wevers, Martine
Naert, Ignace #
Issue Date: Jan-2000
Publisher: American Academy of Implant Dentistry
Series Title: The Journal of Oral Implantology vol:26 issue:1 pages:5-12
Abstract: Qualitative and quantitative analysis of peri-implant tissues around retrieved oral implants is typically done by means of light microscopy on thin histological sections containing the metal surface and the undecalcified bone. It remains, however, a labor-intensive and thus time-consuming job. Moreover, it is a destructive technique that allows tissue quantification in only a limited number of two-dimensional sections. As an alternative, we evaluated the bone structure around screw-shaped titanium implants by means of microfocus computerized tomography (micro-CT) because it presents a number of advantages compared to conventional sectioning techniques: micro-CT is nondestructive, fast, and allows a fully three-dimensional characterization of the bone structure around the implant. Images can be reconstructed in an arbitrary plane, and three-dimensional reconstructions are also possible. Because of its high resolution, individual trabeculae can be visualized. The accuracy of micro-CT was qualitatively evaluated by comparing histological sections with the corresponding CT slices for the same specimen. The overall trabecular structure is very similar according to both techniques. Even very close to the interface, the titanium implant does not seem to produce significant artifacts. Furthermore, because the complete digital data on the trabecular bone structure around the implant is available, it is possible to create finite-element models of the bone-implant system that model the trabeculae in detail so that mechanical stress transfer at the interface can be studied at the level of individual trabeculae. Therefore, micro-CT seems to be very promising for the in vitro assessment of the three-dimensional bone structure around oral implants. Further research will be needed to evaluate its accuracy in a more quantitative way.
Description: CD-rom
ISSN: 0160-6972
Publication status: published
KU Leuven publication type: IT
Appears in Collections:Prosthetics
Mechanical Metallurgy Section (-)
Biomechanics Section
× corresponding author
# (joint) last author

Files in This Item:
File Description Status SizeFormat
pub00169.pdfMain article Published 484KbAdobe PDFView/Open Request a copy

These files are only available to some KU Leuven Association staff members


All items in Lirias are protected by copyright, with all rights reserved.