Title: Progressive versus constant tapered shaft design using NiTi rotary instruments
Authors: Bergmans, Lars ×
Van Cleynenbreugel, Johan
Beullens, M.
Wevers, Martine
Van Meerbeek, Bart
Lambrechts, Paul #
Issue Date: Apr-2003
Publisher: Boston
Series Title: International Endodontic Journal vol:36 issue:4 pages:288-295
Abstract: AIM: To evaluate the influence of a progressive versus constant tapered shaft design on canal preparation by NiTi rotary techniques. METHODOLOGY: A XMCT-scanner and custom-made software were used to nondestructively analyse the mesial canals of 10 extracted mandibular molars in 3D with a spatial resolution of 12.5 microm. Specimens (n = 10 per group) were scanned before and after preparation using ProTaper (progressive tapered) or K3 (constant tapered) files. Numerical values for volume, curvature, dentine removal and centring ratio were obtained in addition to a visual inspection for canal aberrations. Data were analysed by (multiway factorial) anova, Wilcoxon tests and t-tests. RESULTS: The volume of total dentine removal (mean +/- SD) was 1.21 +/- 0.66 mm(3) (ProTaper) and 1.06 +/- 0.23 mm(3) (K3) (P > 0.05), and the amount of dentine removal at all separate horizontal regions examined was comparable for both groups. The mean linear dentine removal (transportation) was in the range of 8-212 microm (ProTaper) and 4-187 microm (K3). The resultant centring ratio varied from 0.01 to 0.24 (ProTaper) and from 0.01 to 0.17 (K3), whilst different straightening patterns were observed. A centre displacement towards the furcation coronally was most pronounced for the ProTaper group whereas a centre displacement towards the outer side of the curvature more apically was only observed for the K3 group. No severe canal aberrations were found. CONCLUSIONS: The progressive tapered shaft design of the ProTaper instrument was less influenced by the mid-root curvature than the constant tapered design of the K3 instrument thereby providing a good centred apical preparation. However, ProTaper instruments tended to transport towards the furcation in the coronal region.
Description: Bergmans L., Van Cleynenbreugel J., Beullens M., Wevers M., Van Meerbeek B., Lambrechts P., ''Progressive versus constant tapered shaft design using NiTi rotary instruments'', International endodontic journal, vol. 36, no. 4, pp. 288-295, April 2003, Blackwell Publishing Ltd.
ISSN: 0143-2885
Publication status: published
KU Leuven publication type: IT
Appears in Collections:Mechanical Metallurgy Section (-)
Biomaterials - BIOMAT
ESAT - PSI, Processing Speech and Images
Department of Oral Health Sciences - miscellaneous
× corresponding author
# (joint) last author

Files in This Item:
File Description Status SizeFormat
pub02291.pdfMain article Published 173KbAdobe PDFView/Open Request a copy

These files are only available to some KU Leuven Association staff members


All items in Lirias are protected by copyright, with all rights reserved.

© Web of science