Title: The sensitivity and specificity of TOP, FDP and GDX in screening for early glaucoma
Authors: Fabré, K ×
Michiels, I
Zeyen, Thierry #
Issue Date: 2000
Series Title: Bulletin de la Société belge d'ophtalmologie vol:275 pages:17-23
Abstract: The purpose of this study was to evaluate the efficacy of three screening tests in detecting glaucoma in its early stage: the Tendency Oriented Perimetry (TOP) and Frequency Doubling Perimetry (FDP) visual field tests, and the Glaucoma Diagnostic (GDx) nerve fibre layer analyser. Eighteen patients with glaucoma who showed an early defect on HFA c 24-2 and twenty normals underwent the three tests. TOP showed a sensitivity of 94.4% and a specificity of 75%, FDP showed a sensitivity of 72.2% and a specificity of 100%, and GDx a sensitivity of 77.7% and a specificity of 60%.
ISSN: 0081-0746
Publication status: published